What information is stored in this tool?

I have summarized what data is stored in the result html file for EnergyPlus and for what the data can be utilized.
If you have some item, you want to visualize, please post new issue here or send email to katsuya.obara@arup.com

Already Visualized
Will be visualized

Items Useful parameter Which page? Required for LEED csv file name
0 Site and Source Energy Energy Use Intensity [kWh/m2]
Total Energy Consumption [kWh]
project detail page Yes
1 Site to Source Energy Conversion Factors
2 Building Area Total Building Area [m2]
Net Conditioned Building Area[m2]
Unconditioned Area[m2]
project detail page Yes
3 End Uses Energy consumption breakdown [kWh] project detail page Yes Energy.csv
4 End Uses By Subcategory
5 Utility Use Per Conditioned Floor Area Energy Use Intensity [kWh/m2] for subcategory such as Lighting,HVAC etc
6 Utility Use Per Total Floor Area Energy Use Intensity [kWh/m2] for subcategory such as Lighting,HVAC etc
7 Electric Loads Satisfied
8 On-Site Thermal Sources
9 Water Source Summary
10 Setpoint Not Met Criteria Tolerance for Setpoint Not Met Time will be Yes
11 Comfort and Setpoint Not Met Summary Unmet Hour during heating/cooling project detail page Yes
12 General Weather File Program Version
13 Window-Wall Ratio Window to Wall Ratio for each direction project detail page Yes WWR.csv
14 Conditioned Window-Wall Ratio Window to Wall Ratio for conditioned area WWRcon.csv
15 Skylight-Roof Ratio will be Yes
16 Zone Summary People Density[ppl/m2]/LPD[W/m2]/Small power[W/m2] for each zone Basic info page Zone.csv
17 End Uses at Peak time Energy consumption breakdown at peak time[W] will be Yes
18 End Uses By Subcategory at Peak time Energy consumption breakdown at peak time[W] will be Yes
19 Source Energy Use Components Summary Weather File Program Version
20 Source Energy Use per Conditioned area ELUIcon.csv
21 Source Energy Use per total floor area ELUI.csv
22 SizingPeriod:DesignDay
23 Weather Statistics File
24 Opaque Exterior U-Factor
Reflectance
Gross Area
will be Yes Opaque.csv
25 Exterior Fenestration U-Factor
SHGC
Transmittance
Gross Area
will be Yes Glass.csv
26 Interior Fenestration
27 Exterior Door
28 Sunlit Fraction
29 Window Control
30 Interior Lighting will be Yes Light.csv
31 Daylighting
32 Exterior Lighting
33 Central Plant Nominal Capacity
Nominal Efficiency
IPLV
will be Yes
34 Cooling Coils Design Coil Load[W]
Nominal Capacity(Sensible/Latent)[W]
will be Yes
35 DX Cooling Coils
36 DX Cooling Coil ASHRAE 127 Standard Ratings Report
37 DX Heating Coils
38 Heating Coils will be Yes
39 Fans Total Efficiency[W/W]
Delta Pressure[Pa]
Max Air Flow Rate[m3/s]
Rated Electric Power[W]
Yes Fan.csv
40 Pumps Head[Pa]
Water Flow[m3/s]
Electric Power[W]
Motor Efficiency[W/W]
will be Yes Pump.csv
41 Service Water Heating Storage Volume[m3]
input[W]
Thermal Efficiency [W/W]
Recovery Efficiency[W/W]
Energy Factor
Yes HW.csv
42 Zone Cooling Design Coil Load[W]
Design Air Flow[m3/s]
Minimum Outdoor Air Flow Rate[m3/s]
will be Yes Cooling.csv
43 Zone Heating Design Coil Load[W]
Design Air Flow[m3/s]
Minimum Outdoor Air Flow Rate[m3/s]
will be Yes
44 System Design Air Flow Rates Air Flow Rate for cooling/heating[m3/s]
45 Plant Loop Coincident Design Fluid Flow Rate Adjustments
46 Economizer
47 Demand Controlled Ventilation using Controller:MechanicalVentilation
48 Time Not Comfortable Based on Simple ASHRAE 55-2004
49 Time Setpoint Not Met Unment hour[h] will be Yes UnmetDetail.csv
50 Average Outdoor Air During Occupied Hours Mechanical Ventilation[ACH]
Simple Ventilation[ACH]
OAaverage.csv
51 Minimum Outdoor Air During Occupied Hours Mechanical Ventilation[ACH]
Simple Ventilation[ACH]
OAmin.csv
52 Surface by Class
53 HVAC Number of HVAC Air Loops / Conditioned Zones / Unconditioned Zones HVAC.csv
54 Input Fields
55-62 Annual and Peak Values Maximum Electricity Consumption[W] will be Yes
63 Annual Building Sensible Heat Gain Components HVAC Zone Eq & Other Sensible Air Cooling[kWh]
HVAC Terminal Unit Sensible Air Cooling[kWh]
Heat Balance Page HeatBalance.csv
64 Peak Cooling Sensible Heat Gain Components HVAC Zone Eq & Other Sensible Air Cooling[W]
HVAC Terminal Unit Sensible Air Cooling[W]
will be
65 Peak Cooling Sensible Heat Gain Components HVAC Zone Eq & Other Sensible Air Cooling[W]
HVAC Terminal Unit Sensible Air Cooling[W]
will be
66 System Ventilation Requirements for Cooling will be Yes

*This structure is based on KingsRoad project